Dielectric insulating blankets, made to measure

The blanket covers and insulates the energized part: busbars, terminals, cables, insulators, crossarms. It is made of elastomer to EN 61112:2009, in six classes, and in the shape each job requires.

Macker dielectric insulating blanket
EN 61112:2009Standard for insulating blankets
Six classesFrom 500 V to 36,000 V. Classes 00, 0, 1, 2, 3 and 4, for alternating current

Choose your blanket

The class is chosen by the installation voltage. Thickness increases with class: the higher the voltage, the more insulating material.

The color depends on the standard

EN 61112 blanketsAll beige
ASTM D1048 blanketsAll orange

In both, the class is identified by a color mark. The color of each class is shown in the table below.

All
By class
ClassCodeUse · ACUse · DCThicknessRoutine testWithstand voltage
Class 00MD00500 V—1.2 to 1.5 mm2.5 kV5 kVView datasheet
Class 0MD01,000 V1,500 V1.9 to 2.2 mm5 kV10 kVView datasheet
Class 1MD017,500 V11,250 V3.0 to 3.6 mm10 kV20 kVView datasheet
Class 2MD0217,000 V25,500 V3.5 to 3.8 mm20 kV30 kVView datasheet
Class 3MD0326,500 V39,750 V3.7 to 4.0 mm30 kV40 kVView datasheet
Class 4MD0436,000 V54,000 V4.0 to 4.3 mm40 kV50 kVView datasheet
Routine test

The voltage applied to every blanket for one minute before it leaves the plant.

Withstand voltage

The voltage it withstands for three minutes without failing in the type test.

Class 00 is the only one with no declared DC value.

Length and width tolerance: ±2 %.

Mat or blanket

They are different products and one does not replace the other. Most jobs use both.

Mat in front of a switchboard
Insulating mat

Insulates the worker from the floor

It goes on the floor, in front of the switchboard or switchgear cell. It breaks the path of the current to earth through the worker's body.

Where it goeson the floor, under the technician's feet
What it protectsthe person
Formaton a roll 600 to 1000 mm wide, or individual from 600 × 1000 mm. Supplied in a bag
View dielectric insulating mats
Blanket covering busbars and terminals
Insulating blanket

Covers the energized part

It goes over the equipment. It covers busbars, terminals, cables, insulators and crossarms so there is no accidental contact while working next to them.

Where it goesover the installation
What it protectsthe worker from the equipment, and the equipment from a short circuit
Formatmade to measure, in the shape of each job

It is the product used for maintenance work on live networks, switchgear and switchboards.

Tests it passes

The values come from each class's datasheet, tested to EN 61112:2009.

TestStandard requirementMacker result
Tensile strength12 MPa minimum16 MPa
Elongation at break300 % minimum350 %
Mechanical puncture resistanceDepends on class30 to 55 N
Tension set15 % maximum12 %
Aging 168 h at 70 °CLoss no greater than 20 %Retains 90 %
Flame retardancy50 mm maximum diameter30 mm
Low-temperature foldingNo cracks or fissuresPass
Marking durabilityWash-resistantPass

Puncture resistance, by class

Class 00Class 0Class 1Class 2Class 3Class 4
Standard requirement25 N30 N45 N45 N45 N45 N
Macker result30 N40 N50 N55 N55 N55 N
Composition

Elastomer.

Appearance

Free of irregularities on both surfaces.

Marking

Name and identification, wash-resistant.

Use, inspection and storage

Before each use

Visual inspection of both faces: cuts, cracks, punctures
Check that the class matches the installation voltage
Secure the blanket so it does not shift during work

Care and testing

Dielectric strength test at least once a year
Replace immediately if it has taken an actual discharge
Gentle cleaning; store dry and out of direct sunlight
Do not store it always folded along the same crease or compressed

Which blanket do you need?

Size, shape and quantity to order. Send us these details and we will make the blanket for that job, with the datasheet for its class.

Installation voltageThe maximum voltage you will be working at
What needs coveringBusbars, terminals, cables, insulators, crossarms
Shape requiredPlain, slit or with eyelets
Size and quantityLength, width and number of pieces